DN-T10GRN-A
|
DINnector
|
Terminal
|
DINnector screw single-level feedthrough terminal block, accepts wire size 24-10 AWG, green, 30A, 35mm DIN rail mount, 100kA SCCR. Package of 100. For use with jumpers DN-24J4Y, DN-2J4Y and DN-3J4Y.
Picture:
Layout view:
|
|
|
|
DN-T12-A
|
DINnector
|
Terminal
|
DINnector screw single-level feedthrough terminal block, accepts wire size 24-12 AWG, gray, 20A, 600V rated (UL), 35mm DIN rail mount, 100kA SCCR. Package of 100. For use with jumpers DN-24J2Y, DN-2J2Y and DN-3J2Y.
Picture:
Layout view:
|
|
|
|
DN-T12B-A
|
DINnector
|
Terminal
|
DINnector screw single-level feedthrough terminal block, accepts wire size 24-12 AWG, blue, 20A, 600V rated (UL), 35mm DIN rail mount, 100kA SCCR. Package of 100. For use with jumpers DN-24J2Y, DN-2J2Y and DN-3J2Y.
Picture:
Layout view:
|
|
|
|
DN-T12RED-A
|
DINnector
|
Terminal
|
DINnector screw single-level feedthrough terminal block, accepts wire size 24-12 AWG, red, 20A, 600V rated (UL), 35mm DIN rail mount, 100kA SCCR. Package of 100. For use with jumpers DN-24J2Y, DN-2J2Y and DN-3J2Y.
Picture:
Layout view:
|
|
|
|
DN-TL14-A
|
DINnector
|
Terminal
|
DINnector screw triple-level feedthrough terminal block, accepts wire size 26-14 AWG, gray, 10A, 300V rated (UL), 35mm DIN rail mount, 10kA SCCR.
Picture:
Layout view:
|
|
|
|
DN-TL14S-A
|
DINnector
|
Terminal
|
DINnector screw triple-level feedthrough terminal block, accepts wire size 26-14 AWG, gray, 10A, 300V rated (UL), 35mm DIN rail mount, 10kA SCCR.
Picture:
Layout view:
|
|
|
|
DN3PS2-33PS02
|
Schmersal
|
Safety Relay
|
Sensorless standstill monitoring of electric drives
Picture:
Layout view:
|
|
|
|
DNG 75037
|
Hager
|
Wire duct
|
Slotted panel trunking DNG PVC 75x37mm 2m Stone Grey RAL7030 UL94 V0 cover
Picture:
Layout view:
|
|
|
|
DO524
|
ABB
|
DO Module
|
Digital output module. 32 DO: 24VDC 0.5A
Picture:
Layout view:
|
|
|
|
DPB02A15
|
Greystone
|
Pressure transmitter
|
Differential Pressure Transmitter, 0 to 10, 20, 50, and 100 PSI ranges, Armoured Cable, 1.5M (5')
DP Series - Differential Pressure Transmitter quantity
Picture:
|
|
|
|
DPB51CM44
|
Carlo Gavazzi
|
Safety Relay
|
RMS 3-Phase voltage monitoring relay
Picture:
|
|
|
|
DPE09BL
|
Schneider Electric
|
Contactor
|
3HP@ 480V, 24VDC Coil
Picture:
Layout view:
|
|
|
|
DPER04
|
Schneider Electric
|
Overload
|
Thermal overload relay,Easy TeSys DPER,0.40-0.63A,class 10
Picture:
Layout view:
|
|
|
|
DPER14
|
Schneider Electric
|
Overload
|
Thermal Overload Relay, 7-10A, Manual/Automatic Reset
Picture:
Layout view:
|
|
|
|
DPM2-P-2R-HL
|
ProSense
|
Panel Meter
|
ProSense digital panel meter, 1/8 DIN, 14mm 4-digit red LED, pulse and frequency input, (2) 8A SPDT relays output, 20 to 265 VAC/11 to 265 VDC operating voltage.
Picture:
Layout view:
|
|
|
|
DPP120-48-1
|
TDK-Lambda
|
Power supply
|
Power supply, 120W; 48VDC; 2.5A
Picture:
Layout view:
|
|
|
|
DPTA-20-02B
|
ProSense
|
Pressure transmitter
|
ProSense air differential pressure transmitter, -2.0 to +2.0in of water column range, 4-20 mA analog output, 1/4in brass barbed process connection, 12 to 36 VDC operating voltage, screw terminals, 35mm DIN rail or panel mount
Picture:
|
|
|
|
DPTA-20-10
|
ProSense
|
Pressure transmitter
|
Air differential pressure transmitter, 0 to 10in of water column range, 4-20 mA analog output, 1/4in brass barbed process connection, 12 to 36 VDC operating voltage, screw terminals, 35mm DIN rail or panel mount.
Picture:
|
|
|
|
DPTA-20-15
|
ProSense
|
Pressure transmitter
|
ProSense air differential pressure transmitter, 0 to 15.0in of water column range, 4-20 mA analog output, 1/4in brass barbed process connection, 12 to 36 VDC operating voltage, screw terminals, 35mm DIN rail or panel mount.
Picture:
|
|
|
|
DPTA-20-P1
|
ProSense
|
Pressure transmitter
|
Air differential pressure transmitter, 0 to 0.1in of water column range, 4-20 mA analog output, 1/4in brass barbed process connection, 12 to 36 VDC operating voltage, screw terminals, 35mm DIN rail or panel mount.
Picture:
|
|
|
|
DPTA-20-P1B
|
ProSense
|
Pressure transmitter
|
Air differential pressure transmitter, -0.1 to +0.1in of water column range, 4-20 mA analog output, 1/4in brass barbed process connection, 12 to 36 VDC operating voltage, screw terminals, 35mm DIN rail or panel mount.
Picture:
|
|
|
|
DPTA-20-P25
|
ProSense
|
Pressure transmitter
|
Air differential pressure transmitter, 0 to 0.25in of water column range, 4-20 mA analog output, 1/4in brass barbed process connection, 12 to 36 VDC operating voltage, screw terminals, 35mm DIN rail or panel mount.
Picture:
|
|
|
DR06D06
|
Crydom
|
Relay
|
Crydom Solid State Relay
Layout view:
|
|
|
|
DRA-40-12
|
MEAN WELL
|
Power supply
|
12V / 3.34A DIMMING DIN RAIL POWER SUPPLY
Picture:
Layout view:
|
|
|
DRC12-40PA
|
TE Connectivity
|
Connector
|
40-Pin DRC Flanged Receptacle
Layout view:
|