Parts Catalogue
Get access to multiple electrical parts and components in SkyCAD file format, all created and shared by the SkyCAD user community.
By allowing SkyCAD to automatically share electrical parts you create and modify, you will get access to the entire on-line catalogue.
Check out the short video tutorial for more details.
Got a question or issue? Reach the on-line catalogue forum
| Part number | Manufacturer | Class | Description | ||
|---|---|---|---|---|---|
|
|
FMB 01 D W24
|
Carlo Gavazzi
|
Relay
|
TIMER MULTI FONCTION
Picture:
Layout view:
|
|
|
|
FMM100-1002
|
ProSense
|
Sensor
|
ProSense liquid flow meter, magnetic-inductive, 1 inch female NPT process connection, 0 to 26.4 GPM, -4 to 176 F, Output: analog, Output 2: analog, 20 to 30 VDC operating voltage.
Picture:
|
|
|
|
FMP09060WH
|
FACTORYMATION
|
Location
|
White Sub Panel for FAS, FUS, and FSR Enclosures. To fit enclosures 35" x 24" (900 x 600mm - HxW), 0.1'' (2.5mm) carbon steel.
Picture:
Layout view:
|
|
|
|
FN2090-10-06
|
TE Connectivity
|
Filters
|
Schaffner, FN2090-10-06, 250 VAC, 50/60 Hz, 10A
Picture:
Layout view:
|
|
|
|
FNQ-R-10
|
Bussmann
|
Fuse
|
Eaton Bussmann Series Class CC fuse, FNQ, time-delay, dual-element current limiting fuse, 10 Amp rejection style fuse, interrupting rating of 200kA at 600Vac
Picture:
|
|
|
FOX.TX.0500.3
|
Foxtam
|
Transformer
|
Transformer, 800VA, primary 230/400v, secondary 55v-0-55v
Layout view:
|
|
|
|
FR 1630-M2
|
Pizzato
|
Limit switch
|
Pizzato, Roller Lever Limit Switch, 1xNO, 1xNC
Picture:
|
|
|
|
FR-HAL-H0.75K
|
Mitsubishi Electric
|
Line Reactor
|
Line reactor, 400V class, 3-phase, 0.75kW (1HP)
Picture:
Layout view:
|
|
|
|
FR-HAL-H1.5K
|
Mitsubishi Electric
|
Line Reactor
|
Line reactor, 400V class, 3-phase, 1.5kW (2HP)
Picture:
Layout view:
|
|
|
|
FRN-R-30
|
Bussmann
|
Fuse
|
BUSSMANN Fuse: 30 A, 250V AC, 2 in L x 9/16 in dia Fuse Size, Cylindrical Body, FRN-R
Picture:
|
|
|
|
FSPDB2A
|
Mersen
|
Power Distribution Block
|
Single Pole, 175A,1500VAC/DC
Picture:
Layout view:
|
|
|
|
FT-1-1586C42G36
|
ABB
|
Test Port
|
Standard 10-pole flexitest with 3 current shorting pairs (black), 3 potential (black) and 1 potential (red). Shorting pairs are make before break with test jack and blade. Potential switches are non-shorting blade.
Standard mounting depth and solid black "ABB" cover plate.
Picture:
Layout view:
|
|
|
FTEC16L4X-24DSB
|
Arieltech
|
Fan
|
Arieltech Fans, FTEC 16 Series
Layout view:
|
|
|
|
FTM-VT04UV
|
FMX
|
Enclosure accessory
|
FTM-VT04UV
Picture:
Layout view:
|
|
|
|
FTM50-AGG2A2A12AA
|
Endress Hauser
|
Proxy Switch
|
Vibronic Point level detection Soliphant FTM50
Picture:
|
|
|
|
FU-77TZ
|
Keyence
|
Photocell
|
Fiber Unit Thrubeam. HEX-shaped.
Picture:
|
|
|
FUS1208040
|
FMX
|
Location
|
Enclosure 12, 47 x 31
Layout view:
|
|
|
FX-301
|
Panasonic
|
Sensor
|
Fiber Optic Sensor, FX-300 Series, Standard Type, Red LED, NPN
Layout view:
|
|
|
|
FX3U-48MT_DSS
|
Mitsubishi Electric
|
PLC
|
PLC, FX3U Base Unit DC 24 V: 24 inputs DC 24 V; 24 transistor outputs
Picture:
Layout view:
|
|
|
|
FX5-4AD-ADP
|
Mitsubishi Electric
|
PLC Module
|
Analog Input Module, Qty. 4 AI (1-10V, 0-20mA)
Picture:
Layout view:
|
|
|
|
FX5-C16EYR/D-TS
|
Mitsubishi Electric
|
DO Module
|
Compact Digital Output Module, 16 Pt Relay, Spring Clamp Terminals.
Picture:
Layout view:
|
|
|
|
FX5-C32EX/DS-TS
|
Mitsubishi Electric
|
DI Module
|
Compact Digital Input Module, 32 Pt DC IN Sink/Source, Spring Clamp Terminals
Picture:
Layout view:
|
|
|
|
FX5-ENET/IP
|
Mitsubishi Electric
|
Networking
|
Ethernet IP Module
Picture:
Layout view:
|
|
|
|
G07S0000
|
Red Lion
|
HMI
|
7" Graphite Touch Screen
Picture:
Layout view:
|
|
|
|
G10C1000
|
Red Lion
|
HMI
|
GRAPHITE 10" HMI, COLOR, INDOOR, 24 VDC, DUAL ETHERNET
Picture:
Layout view:
|