#1
Version 1.3.13 change log
Version 1.3.13 is now available for download.
Here's an overview of fixes and added features.
Added features:
All Pro features now available.
Additionally, these generic features were added:
V1.3.13
Allow to assign functions to connection port groups
V1.3.12
Add 'Connected to' column in terminal lug connection dialogue box.
V1.3.7
Add 'ShowConnectedSideLabel' to graphical terminal junction class.
Define new IF query comparator special character sets based on XML special characters.
V1.3.6
Faster file loading process
Establish Terminal/terminal strip representation in harness overview.
Allow for cable wires to be routed outside of their cable route.
Display location deletion warning message only if parts are assigned in it AND laid-out.
Inserting terminal strip block should trigger terminal strip creation process.
Change 'saved to catalogue.' message to 'successfuly saved.'
Make it so location symbol links to the same location when copied instead of creating a new one
V1.2.208
Freeze contextual revision of external references when they are used in a Project/System.
Allow to use internal revisions
Automatic packaging and sending to on-line catalogue of saved catalogue parts.
Add 'GetLocatedInStructure' query
Allow converting System to Project.
Verify package version before opening - cancel if version is newer than SkyCAD's version.
When browsing class catalogue, add button to access Community Catalogue.
Allow 'Type' and 'Start value' settings of Numbering formats to process queries.
Add a 'Request a trial license' button in the license level warning message box.
Add a command button in Catalogue tools to directly add part package to environment.
Allow to merge two classes together
Allow to prioritise a particular linked block when sorting work objects for numbering.
Do not reset revision date when closing if a date was manually defined.
Allow to paste a PLC Coupler on a project
Add a list of file extensions supported by 'File' type and 'Web link' value holders.
V1.2.195
Allow to show all wires (including cable wires) going through a harness branch. (GetAllRoutedWires)
Do not create wires for connections connecting bridged terminals.
Add 'GetFilePath' query to SkyCAD Objects.
Delete a dimension when dimension text is selected and user acvtivate deletion.
Allow expression evaluation (math formulas) in property values
Add 'IsFieldDevice' query to generate BOMs of field device.
Add 'IsSubLocationOf' query to the 'Location' class
DisplayedLabel improvement: show Catalogue ID in parenthesis when class name is shown.
V1.2.194
Include a 'Repeat' query parameter to allow listing objects a certain number of time.
Make it so Harness boots can have splice connection point groups.
Allow to invert source and destination of a single wire
Allow to force a property initial value as the default value
Allow to trigger wire processing on single connection group from selected connection
V1.2.192
Allow for System's CatalogueID to be listed in parts-list/BOMS instead of their sub-parts.
Allow to trigger wire processing on single connection group from selected connection
V1.2.190
Include open Tabs in 'hamburger' menu of view tab area to access them directly.
Allow to display location BOMs
Components with options should be accessible from the options tree view.
V1.2.183
- Oriented connection reset upon wire info symbol insertion.
- 'Drawing/Add component property' should work for layout blocks as well.
- Keep insert symbol on axis enabled when library thumbail is locked.
- Allow to reach previously active View Tab.
- Generic improvements of Design-by-Systems, Configuration mamagement and Harness design features.
V1.2.169
- Improved harness features and library
V1.2.165
- Define a 'Assign to PLC' feature.
- Add a 'GetConnectedElements' query to OPR.
- Make 'Flow through' checkbox visible for connector pins
V1.2.162
- Allow to increase all text sizes using a ratio stored in an environment setting.
- Defined a 'Coupler' class to manage Remote IOs
- Add 'LastItem' parameter to query, which acts like 'Item' but count backwards.
- Allow to reach previously active View Tab.
Bugs fixed:
V1.3.13
GetExtendedID query should take into consideration 'Show Work ID value on sub-parts'.
Package extraction will not work if SkyCAD environents folder is not on C:\ drive.
V1.3.12
Graphical terminal junction symbols still default to 'Explore terminal' in some cases.
White/pale color text are printed black when 'print to monochromeM' is activated.
View tab still active after project close, creates rendering issues.
OPRs cannot be linked if they are at the exact same position on different sheets.
GetAllTerminalStrip query does not go past two hierarchical levels.
V1.3.10
Connection merge process should favor lower level hiearchical level connection.
V1.3.8
Incorrect option assignement to modified data in some hierarchical structure
Context property priority not taken into consideration for accessories.
V1.3.7
Virtual part becomes hidden with V1.3.6.
V1.3.6
Sub-Component/accessory locatedIn value cashed and not reset when parent component changes location.
Cable wire connected to terminal does not take into consideration terminal strip connectivity info.
Revision property definition settings should not all be read-only.
Drill hole pattern doesn't show dimensions of laid-out parts anymore.
Copy/paste process interupted if terminal strip layout instance is copied.
Connector pin navigation objects should include connector symbols.
V1.3.0
Issue with empty tag value of distribution terminal symbol in some situations
Copying elements from System to parent project/System resets entire element's sub-structure
Process wires on multiple selected connections stops after first wire creation.
Issue copying a grouping within a System
Error message not displayed when pasting incompatibility is detected and cancels paste.
'Options' tree view element remains sometime in option tree after after closing Project/system.
Title block not inserted automatically at sheet creation
V1.2.212
Issue with empty tag value of distribution terminal symbol in some situations
V1.2.211
Issue with automatic upload of saved parts to online catalogue
V1.2.210
Three view does not get automatically redrawn after hitting 'Save All'.
Linking PLC module blocks leaves a 'phantom' PLC module instead of deleting it after linking
V1.2.209
Three view does not get automatically redrawn after hitting 'Save All'.
V1.2.208
Terminal strip layout: do not draw bridge dot if bridge line won't be draw,
OPR cross reference does not always appear automatically after linking...
Keybord shortcuts stop working if Windows button was pressed once.
Location creation process won't use customised sub-class
Location BOM lists location part-number, but with a 0 quantity.
Issue sorting a grid when items are shown more than once.
Inserting a cable indicator while hold SHIFT does not display dialogue box.
Implemented elements show elements as many times as harness connections touch them.
Moving connection point block does not stretch connections.
Additional drawing obects in location block are not drawn.
Clicking the background of a sheet while pressing CTRL adds the sheet to selected objects.
Buttons too small for high resolution
Embedded IF queries gets wrong value when two properties have embedded IF queries.
Project's 'Catalogue Index Property' class setting is set to 'Read-Only' and should not.
Text template used for showing properties around symbols not accessible.
"Tag" property definition should be set to 'Read-Only' so users can't change its settings.
Cross-rererence display issue when rotated,
CatalogueID property definition should not be configurable.
Inserting a grouping with oriented connections is canceled out.
PLC ends-up with 'phantom' modules after saving in context of a project (and PLC has sub-modules...)
Change package import confirmation message to 'Package succesfully imported.'
V1.2.195
Issue mapping catalogue cable to in-context cable when sub-cables are defined.
None printable objects are exported to DWG nonetheless
Swap wires should look all the way up to the top-most cable, not the immediate parent cable.
Change package import confirmation message to 'Package succesfully imported.'
Can't insert revision in System when system is used within a project.
Connection point blocks get deleted when parent workblock is linked to abother component.
F5 shortcut key not associated to 'Assign from catalogue' when a layout instance is selected.
Unflag 'SystemObject' and 'ReadOnly' from copied objects
Schematics terminal strip layout can now only be selected by clicking the header symbol
V1.2.194
Shortcut keys are triggered when other keys are pressed at the same time.
Can't close an element that is revision locked.
Location BOM doesn't list Location part-number. It should.
V1.2.192
Changing order of children object may not work in some rare cases.
Renumbering process should not be allowed to get launched when Root object is revision locked.
V1.2.191
Allow for System's CatalogueID to be listed in parts-list/BOMS instead of their sub-parts.
Cabling info not displayed beside cable indicator when cable is within a grouping inside a sheet.
V1.2.190
Treeview refresh issue on Opening saved elements
'Assign from catalogue' button not available when terminal symbol is selected.
Assigning part number for terminal not shown in schematics will lose saved conectivity.
Excel/CSV export does not clean '#ERROR: No such query' values.
Distribution terminal index not evaluated if connected to more than one item in schematics.
Connector pins not listed in BOM
Issue with Cut/Paste of folder.
V1.2.183
- Last rung number of first column sometimes same value as first rung of second column.
- 'Explore single wires' on connection does nothing if multiple single wires are associated to it.
- 'Layout element' and 'Layout sub-part' should not allow to select main block.
- Issue with ribbon when selected objects are removed through undo.
- 'Hide cable information' not taken into consideration when exporting to DWG/DXF
- Wire list tree view query not sorted by wire number.
- Wrong query used when 'assign from catalogue' is triggered from a cable connection.
- Issue in 'Left justify' and 'Right justify' rail positioning calculation.
- Typo in 'Show terminal strip elements' query on Terminal Strip.
- Refresh required when changing channel type in Block generator View.
- Clicking on web link cell won't work if cell is read-only.
V1.2.171
- Wire list query crashes SkyCAD when a large amount of wires is implicated.
V1.2.165
- Wire list empty when working with project using wires in version 1.2.131.
- Images printed in color even if 'Print to monochrome' is activated.
- Make sure exported values in CSV file are between quotes.
- View tab label empty for none graphical elements displayed.
- Pasting a location symbol triggers Explorer display while UI is locked if location is not present.
- Some harness branches being unnecessarily reset when running wire processing
V/1.2.162
- Issue with Cut/Paste of folder.
- Make it so Text created from text templates transfer raw values of each text properties.
- Contextual IO Information is saved with component when saved to catalogue.
- Ampersand character does not show in DropDown list
- Cable indicator wire information does not show if cable shown is sub-cable.
- Allow for the Block Generator to manage blocks for accessories.
- Resolve connectivity should not remove already resolved 'Connected To' fields.
- Terminal junction display issue on source/destination cable wires.
- Cable indicator within location symbols make it so cables are located -- they should not.
- Printable check box has no effect on text objects.
- Cabling info on Cable Indicator not updated upon first sheet display.
- Cable wiring process does not properly take into consideration OPRs.
- Connector part number is not saved within grouping
- Distribution block navigation points to wrong terminal sometimes
- Filter by location property definition shouldn't be 'ReadOnly'
- Prevent being able to link between elements not sharing the same root object.
- Ground terminal icon not showing ground when more than one ground junction...
- Navigation for terminal junctions won't work in some occasions.
- Text templates do not transfer angle property to created texts.
- Stacking terminals makes it so terminal junctions lose connectivity info.
- Issue sorting graphical objects: overlapping objects get skipped.
- Wrong query used when 'assign from catalogue' is triggered from a cable connection.
- Issue in 'Left justify' and 'Right justify' rail positioning calculation.
- Typo in 'Show terminal strip elements' query on Terminal Strip.
- Clicking on web link cell won't work if cell is read-only.
- Hidden connection text get exported nonetheless in DWG export process. They shouldn't.
- Potential OPR positions not calculated upon sheet opening.
- Do not clear clip-board when ESC is pressed.
- Starting SkyCAD forces the 'ID Property' class setting for accessory to 'Tag'